Cavity Filter Series


ClearComm Technologies Lowpass Filters are produced to our customer's individual requirements. The use of common components and housings allows us to produce these filters with minimal engineering time.

In cases where there is not an existing specification detailing the electrical and physical parameters of the filter, ClearComm can provide a response based on completing the table below.


ELECTRICAL AND MECHANICAL REQUIREMENTS
Parameter Value Notes
Center Frequency   Or Lower and Upper Bandedge
Bandwidth   Usually given as 3 dB point
Insertion Loss   At Center Frequency
VSWR (Return Loss)   Typically 1.5:1 (14 dB)
Stopband Rejection(s)   Given as Attenuation and Frequency
Power Handling   Typically 1-10 W Avg.
Package Style   See Outlines or provide drawing
Connectors   BNC Female, BNC Male, Blind Mate, 'N' Female, 'N' Male,
RF PIN (2), SMA Female, SMA Male
TNC Female, TNC Female
Environmental and Mechanical   You may specify Humidity, Shock, Vibration, Temperature Range,
Altitude, Gross / Fine Leak, Etc.
Quantity Required   Please give range of quantities required
Delivery Requirements   Time frame for deliveries